  "commit": "6a3566773f3b52550ebf0d042154958a2403bb40",
  "tree": "7bbac5f06d146e73eb278edc6c166fbe4f6cad5d",
  "parents": [
    "d55afebf8bc03f87d1a8b8f92144c2f8da6ca0ae"
  ],
  "author": {
    "name": "Nico Huber",
    "email": "nico.huber@secunet.com",
    "time": "Fri Oct 21 15:13:55 2016 +0200"
  },
  "committer": {
    "name": "Nico Huber",
    "email": "nico.h@gmx.de",
    "time": "Sat Oct 29 01:26:24 2016 +0200"
  },
  "message": "gma: Fix loop logic in Scan_Ports()\n\nWhen deciding if a pipe has been configured, we only checked if reading\nthe EDID succeeded not if it contained usable data.\n\nTEST\u003dBooted kontron/ktqm77 with a DVI-I to VGA cable and the display\n     came up (it didn\u0027t before because of a gap in the pipe config, i.e.\n     the second pipe was disabled so coreboot didn\u0027t bother to look at\n     the third).\n\nChange-Id: I10075db8916efcee68be95971145c3f6f1530e5a\nSigned-off-by: Nico Huber \u003cnico.huber@secunet.com\u003e\nReviewed-on: https://review.coreboot.org/17087\nTested-by: Nico Huber \u003cnico.h@gmx.de\u003e\nReviewed-by: Stefan Reinauer \u003cstefan.reinauer@coreboot.org\u003e\n",
  "tree_diff": [
    {
      "type": "modify",
      "old_id": "cd202be4b6429385a9a10c276855c2ef06620368",
      "old_mode": 33188,
      "old_path": "common/hw-gfx-gma.adb",
      "new_id": "e6a5928d0eefee58f876e40d8a0e86534636ae0a",
      "new_mode": 33188,
      "new_path": "common/hw-gfx-gma.adb"
    }
  ]
}